POLAR AUDIOFIELD TOOLS
All tools

Limiter Calculator

Three inputs. Your limiter threshold.

1. Loudspeaker

Use the RMS/AES rating of the connected cabinet or driver, not program or peak watts.

2. Amplifier

dB

Use the gain setting shown in the amplifier manual or on its rear panel. Keep input level controls fully open (0 dB attenuation).

3. Your limiter setting

Enter valid values to calculate.

Practical starting point: set the controller 1–2 dB below this calculated threshold.

What does this mean in volts?

This threshold is in dBu at the analog processor output. 0 dBu = 0.775 V RMS. If your DSP displays dBFS or another dB scale, convert using its documented output reference.

Attack & release · practical starting values

Loudspeaker / bandAttackRelease
2-/3-way fullrange, passive crossover10 ms80 ms
Active low/mid · approx. 50 Hz–1 kHz10 ms80 ms
Subwoofer / low · approx. 30–125 Hz40 ms320 ms
Active mid · approx. 125 Hz–1 kHz4 ms32 ms
Active high · approx. 1–20 kHz1 ms8 ms

Starting values based on the NOVA approach, not model-specific presets. Follow the manufacturer's settings where available. Release = attack × 8.

Delay Calculator

Enter the extra sound path. For alignment at a listening point, delay the speaker whose sound arrives first by this amount.

Based on 20 °C · speed of sound 343 m/s · 1 m ≈ 2.92 ms. Acoustic travel time only; equipment latency is not included.

All tools

Practical guidance for voltage-source amplifiers. Nominal impedance is an approximation. Threshold, timing and suitable crossover/high-pass settings work together; these values are not a complete protection preset.