Limiter Calculator
Three inputs. Your limiter threshold.
1. Loudspeaker
Use the RMS/AES rating of the connected cabinet or driver, not program or peak watts.
2. Amplifier
Use the gain setting shown in the amplifier manual or on its rear panel. Keep input level controls fully open (0 dB attenuation).
3. Your limiter setting
Enter valid values to calculate.
Practical starting point: set the controller 1–2 dB below this calculated threshold.
What does this mean in volts?
This threshold is in dBu at the analog processor output. 0 dBu = 0.775 V RMS. If your DSP displays dBFS or another dB scale, convert using its documented output reference.
Attack & release · practical starting values
| Loudspeaker / band | Attack | Release |
|---|---|---|
| 2-/3-way fullrange, passive crossover | 10 ms | 80 ms |
| Active low/mid · approx. 50 Hz–1 kHz | 10 ms | 80 ms |
| Subwoofer / low · approx. 30–125 Hz | 40 ms | 320 ms |
| Active mid · approx. 125 Hz–1 kHz | 4 ms | 32 ms |
| Active high · approx. 1–20 kHz | 1 ms | 8 ms |
Starting values based on the NOVA approach, not model-specific presets. Follow the manufacturer's settings where available. Release = attack × 8.
Delay Calculator
Enter the extra sound path. For alignment at a listening point, delay the speaker whose sound arrives first by this amount.
Based on 20 °C · speed of sound 343 m/s · 1 m ≈ 2.92 ms. Acoustic travel time only; equipment latency is not included.
Practical guidance for voltage-source amplifiers. Nominal impedance is an approximation. Threshold, timing and suitable crossover/high-pass settings work together; these values are not a complete protection preset.